100S-D250EZJ22BC
250 A MCS D Safety Contactor
Rockwell Automation announces that as of March 31, 2019, the 250 A MCS D Safety Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
March 31, 2019
替代类别:
Engineering Replacement
替代产品:
100S-E265KJ12C
[https://www.rockwellautomation.com.cn/products/details.100S-E265KJ12C.html]
Product at a glance
Rockwell Automation announces that as of March 31, 2019, the 250 A MCS D Safety Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
March 31, 2019
替代类别:
Engineering Replacement
替代产品:
100S-E265KJ12C
[https://www.rockwellautomation.com.cn/products/details.100S-E265KJ12C.html]
Product at a glance
| Voltage type for actuating |
DC
|
|---|---|
| Rated control supply voltage at DC |
24 V
|
| Type of electrical connection of main circuit |
Screw connection
|
| Rated impulse withstand voltage (Uimp) |
12 kV
|
| Current (Ie), max |
250 A
|
| Current rating |
115 A
|
| Main current circuit resistance |
0.22 mΩ
|
| Rated filament current |
250A @ 230/240V, AC-5b
|
| Rated isolation voltage (Ui) |
600V per UL, CSA
|
| Auxiliary contacts |
IP20 IEC 60529/DIN 40050
|
| Rated power (enclosed) |
75Hp @ 200V, 3-phase per UL/CSA
|
| Rated operational current for contactor |
180A @ 460V, elevator duty (UL/CSA)
|
| Rated power for contactor |
60Hp @ 230V, elevator duty (UL/CSA)
|
| Auxiliary contact configuration |
2 NO, 2 NC auxiliary bifurcated
|
| Rating of single capacitor |
98 kVAR @ 230V @ 60Hz, AC-6b, 40 °C
|
| Rating of group capacitors |
98 kVAR @ 230V @ 60Hz, AC-6b, 40 °C
|
| General purpose current (enclosed) |
Load carrying capacity: 300 A per UL/CSA
|
| Operating time, closing delay |
35...110 ms @ DC
|
| Power dissipation |
41.7 W @ 400V, AC-3, Ie
|
| Short time withstand (Icw) |
2520A @ 10s, 60 °C
|
| Operating time, opening delay |
25...50 ms @ DC
|
| Coil consumption, hold-in |
6 W @ DC control
|
| Coil consumption, pick-up |
380VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Total power dissipation |
DC control: 47.7 W @ 400V, AC-3, Ie
|
| Operating limits, dropout |
(0.3...0.5) x Us @ DC control
|
| Switching of lamps |
Gas discharge lA, open: 315A @ 40°C, AC-5a
|
| Insulation class of the coil |
Class B per VDE 0660, table 22
|
| Rating for switching AC motors |
80 kW @ 230V @ 50Hz, 3-phase (AC-2, AC-3)
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ DC control
|
| BS88 fuses current rating |
Type2 (IEC 60947-4-1): 355A @ 415V, 65 kA available fault current
|
| UL class L fuses rating |
700A @ 600V, 18 kA available fault current per UL listed combination
|
| DIN fuses (gG, gL) current rating |
Type2 (IEC 60947-4-1): 400A @ 690V, 50 kA available fault current
|
| Coil voltage |
24V DC electronic coil with electronic interface
|
| Rated operational current (Ie) |
95A @ 1000V, AC-4 (50 Hz), ambient temperature 60 °C
|
| UL class J and CSA HRCI-J fuses rating |
Type2 (IEC60947-4-1): 400A @ 100kA available fault current per UL verified combination
|
| UL inverse-time circuit breaker |
400A @ 600V, 30 kA available fault current per UL listed combination
|
| Switching of power transformers |
Apparent power: 90.1 kVA @ 208V @ 60Hz
|
| Rated operational power (Pe) |
83 kW @ 240V, AC-4 (50 Hz), ambient temperature 60 °C
|
| Switching of DC loads |
3-pole in series: 4.1A @ 440V (shunt-wound motors, starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
|
| Optional accessories |
Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
|
| Features |
Mirror contact performance on auxiliary contacts, which are required in ftdback circuit for modern safety applications, The NC auxiliary contacts will not change state when a power contact welds, SUVA third-party certification, AC and DC operating coils,
|
| Contacts |
3 main poles with N.C. mechanically linked ftdback contacts
|
| Electronic-EI coil type |
Yes
|
| Width |
155 mm
|
|---|---|
| Height |
221.75 mm
|
| Depth |
180.5 mm
|
| Single contactor cover |
IP10 IEC 60529/DIN 40050
|
| Contactor with frame terminal block |
IP20 IEC 60529/DIN 40050
|
| Screw terminals |
Thru-hole
|
|---|---|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Main contact terminal conductor cross section |
6 mm @ maximum s
|
| Frame terminal block conductor cross section |
6...20 mm @ s top
|
| Lifespan |
Mechanical DC control: 10000000 ops
|
| Switching frequency, max |
100 ops/h, AC-4 (approximately 200000 ops)
|
| Recommended torque |
43 Nm
|
| Weight |
Non-reverse: 7.5 kg @ DC
|
| Conductor cross section |
Top opening: 25 to 240 mm²
|
| Protection class |
IP00 IEC 60529/DIN 40050
|
| Altitude of installation site, max |
2000 m (NN) per IEC 60947-4
|
|---|---|
| Protection against accidental contact |
Finger and back-of-hand proof per VDE 0106, part 100
|
| Ambient temperature |
Storage: -40...80 °C
|
| 类型 | 资源 | 出版 |
|---|---|---|
| Installation Instructions | 100s-in009_-en-e | 100S-IN009 |
| Technical Data | 100-td013_-en-p | 100-TD013 |
技术规格
| Voltage type for actuating |
DC
|
|---|---|
| Rated control supply voltage at DC |
24 V
|
| Type of electrical connection of main circuit |
Screw connection
|
| Rated impulse withstand voltage (Uimp) |
12 kV
|
| Current (Ie), max |
250 A
|
| Current rating |
115 A
|
| Main current circuit resistance |
0.22 mΩ
|
| Rated filament current |
250A @ 230/240V, AC-5b
|
| Rated isolation voltage (Ui) |
600V per UL, CSA
|
| Auxiliary contacts |
IP20 IEC 60529/DIN 40050
|
| Rated power (enclosed) |
75Hp @ 200V, 3-phase per UL/CSA
|
| Rated operational current for contactor |
180A @ 460V, elevator duty (UL/CSA)
|
| Rated power for contactor |
60Hp @ 230V, elevator duty (UL/CSA)
|
| Auxiliary contact configuration |
2 NO, 2 NC auxiliary bifurcated
|
| Rating of single capacitor |
98 kVAR @ 230V @ 60Hz, AC-6b, 40 °C
|
| Rating of group capacitors |
98 kVAR @ 230V @ 60Hz, AC-6b, 40 °C
|
| General purpose current (enclosed) |
Load carrying capacity: 300 A per UL/CSA
|
| Operating time, closing delay |
35...110 ms @ DC
|
| Power dissipation |
41.7 W @ 400V, AC-3, Ie
|
| Short time withstand (Icw) |
2520A @ 10s, 60 °C
|
| Operating time, opening delay |
25...50 ms @ DC
|
| Coil consumption, hold-in |
6 W @ DC control
|
| Coil consumption, pick-up |
380VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Total power dissipation |
DC control: 47.7 W @ 400V, AC-3, Ie
|
| Operating limits, dropout |
(0.3...0.5) x Us @ DC control
|
| Switching of lamps |
Gas discharge lA, open: 315A @ 40°C, AC-5a
|
| Insulation class of the coil |
Class B per VDE 0660, table 22
|
| Rating for switching AC motors |
80 kW @ 230V @ 50Hz, 3-phase (AC-2, AC-3)
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ DC control
|
| BS88 fuses current rating |
Type2 (IEC 60947-4-1): 355A @ 415V, 65 kA available fault current
|
| UL class L fuses rating |
700A @ 600V, 18 kA available fault current per UL listed combination
|
| DIN fuses (gG, gL) current rating |
Type2 (IEC 60947-4-1): 400A @ 690V, 50 kA available fault current
|
| Coil voltage |
24V DC electronic coil with electronic interface
|
| Rated operational current (Ie) |
95A @ 1000V, AC-4 (50 Hz), ambient temperature 60 °C
|
| UL class J and CSA HRCI-J fuses rating |
Type2 (IEC60947-4-1): 400A @ 100kA available fault current per UL verified combination
|
| UL inverse-time circuit breaker |
400A @ 600V, 30 kA available fault current per UL listed combination
|
| Switching of power transformers |
Apparent power: 90.1 kVA @ 208V @ 60Hz
|
| Rated operational power (Pe) |
83 kW @ 240V, AC-4 (50 Hz), ambient temperature 60 °C
|
| Switching of DC loads |
3-pole in series: 4.1A @ 440V (shunt-wound motors, starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
|
| Optional accessories |
Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
|
| Features |
Mirror contact performance on auxiliary contacts, which are required in ftdback circuit for modern safety applications, The NC auxiliary contacts will not change state when a power contact welds, SUVA third-party certification, AC and DC operating coils,
|
| Contacts |
3 main poles with N.C. mechanically linked ftdback contacts
|
| Electronic-EI coil type |
Yes
|
| Width |
155 mm
|
|---|---|
| Height |
221.75 mm
|
| Depth |
180.5 mm
|
| Single contactor cover |
IP10 IEC 60529/DIN 40050
|
| Contactor with frame terminal block |
IP20 IEC 60529/DIN 40050
|
| Screw terminals |
Thru-hole
|
|---|---|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Main contact terminal conductor cross section |
6 mm @ maximum s
|
| Frame terminal block conductor cross section |
6...20 mm @ s top
|
| Lifespan |
Mechanical DC control: 10000000 ops
|
| Switching frequency, max |
100 ops/h, AC-4 (approximately 200000 ops)
|
| Recommended torque |
43 Nm
|
| Weight |
Non-reverse: 7.5 kg @ DC
|
| Conductor cross section |
Top opening: 25 to 240 mm²
|
| Protection class |
IP00 IEC 60529/DIN 40050
|
| Altitude of installation site, max |
2000 m (NN) per IEC 60947-4
|
|---|---|
| Protection against accidental contact |
Finger and back-of-hand proof per VDE 0106, part 100
|
| Ambient temperature |
Storage: -40...80 °C
|
文档
|
100s-in009_-en-e
Installation Instructions
100S-IN009 |
|
100-td013_-en-p
Technical Data
100-TD013 |
| 类型 | 资源 | 出版 |
|---|---|---|
| Installation Instructions | 100s-in009_-en-e | 100S-IN009 |
| Technical Data | 100-td013_-en-p | 100-TD013 |