100S-D115EA22C
115 A MCS D Safety Contactor
Rockwell Automation announces that as of March 31, 2019, the 115 A MCS D Safety Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
March 31, 2019
替代类别:
Engineering Replacement
替代产品:
100S-E116KD12C
[https://www.rockwellautomation.com.cn/products/details.100S-E116KD12C.html]
Product at a glance
Rockwell Automation announces that as of March 31, 2019, the 115 A MCS D Safety Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
March 31, 2019
替代类别:
Engineering Replacement
替代产品:
100S-E116KD12C
[https://www.rockwellautomation.com.cn/products/details.100S-E116KD12C.html]
Product at a glance
| Voltage type for actuating |
AC/DC
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
208 V
|
| Rated control supply voltage at AC 60 Hz |
208 V
|
| Rated control supply voltage at DC |
200 V
|
| Type of electrical connection of main circuit |
Screw connection
|
| Rated impulse withstand voltage (Uimp) |
12 kV
|
| Current (Ie), max |
115 A
|
| Current rating |
115 A
|
| Main current circuit resistance |
0.4 mΩ
|
| Rated filament current |
120A @ 230/240V, AC-5b
|
| Rated isolation voltage (Ui) |
600V per UL, CSA
|
| Auxiliary contacts |
IP20 IEC 60529/DIN 40050
|
| Rated power (enclosed) |
75Hp @ 460V, 3-phase per UL/CSA
|
| Rated operational current for contactor |
80A @ 230V, elevator duty (UL/CSA)
|
| Rated power for contactor |
75Hp @ 575V, elevator duty (UL/CSA)
|
| Auxiliary contact configuration |
2 NO, 2 NC auxiliary
|
| Rating of single capacitor |
97 kVAR @ 500V @ 50Hz, AC-6b, 40 °C
|
| Rating of group capacitors |
58 kVAR @ 1000V @ 50Hz, AC-6b, 60 °C
|
| General purpose current (enclosed) |
Load carrying capacity: 220 A per UL/CSA
|
| Operating time, closing delay |
Electronic coil: 9...18 ms @ RC module
|
| Power dissipation |
14.5 W @ 400V, AC-3, Ie
|
| Short time withstand (Icw) |
1040A @ 10s, 60 °C
|
| Operating time, opening delay |
Electronic coil: 6...12 ms @ AC
|
| Coil consumption, hold-in |
Electronic coil: 8 W @ DC control
|
| Coil consumption, pick-up |
Electronic coil: 650VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Total power dissipation |
DC control: 22.5 W @ 400V, AC-3, Ie
|
| Operating limits, dropout |
Electronic coil: (0.3...0.6) x Us @ DC control
|
| Switching of lamps |
Gas discharge lA, open: 144A @ 40°C, AC-5a
|
| Insulation class of the coil |
Class B per VDE 0660, table 22
|
| Rating for switching AC motors |
80 kW @ 500V @ 50Hz, 3-phase (AC-2, AC-3)
|
| Switching of hermetically sealed cooling compressor motors |
192A @ 690V, AC-8a (manual reset of overload release (50 Hz))
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ DC control
|
| BS88 fuses current rating |
Type2 (IEC 60947-4-1): 200A @ 415V, 65 kA available fault current
|
| UL class K5 and RK5 fuses rating |
250A @ 600V, 10 kA available fault current per UL listed combination
|
| DIN fuses (gG, gL) current rating |
Type2 (IEC 60947-4-1): 200A @ 690V, 50 kA available fault current
|
| Coil voltage |
208-277V 50/60 Hz/230-250 50/60 Hz/200-255V DC electronic coil with electronic interface
|
| Rated operational current (Ie) |
Conventional coil type: 115A @ 690V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C
|
| UL class J and CSA HRCI-J fuses rating |
Type2 (IEC60947-4-1): 200A @ 100kA available fault current per UL verified combination
|
| UL inverse-time circuit breaker |
150A @ 600V, 10 kA available fault current per UL listed combination
|
| Switching of power transformers |
Apparent power: 99.8 kVA @ 480V @ 60Hz
|
| Rated operational power (Pe) |
87 kW @ 240V, AC-1 (50 Hz), ambient temperature 60 °C
|
| Switching of DC loads |
3-pole in series: 3A @ 440V (shunt-wound motors, starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
|
| Optional accessories |
Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
|
| Features |
Mirror contact performance on auxiliary contacts, which are required in ftdback circuit for modern safety applications, The NC auxiliary contacts will not change state when a power contact welds, SUVA third-party certification, AC and DC operating coils,
|
| Contacts |
3 main poles with N.C. mechanically linked ftdback contacts
|
| Conventional coil type |
Yes
|
| Electronic-EI coil type |
Yes
|
| Screw terminals |
Thru-hole
|
|---|---|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Main contact terminal conductor cross section |
8.3 mm @ minimum Ø
|
| Frame terminal block conductor cross section |
3...9 mm @ s top
|
| Lifespan |
Mechanical DC control: 10000000 ops
|
| Switching frequency, max |
120 ops/h, AC-4 (approximately 200000 ops)
|
| Recommended torque |
88 to 106 in-lb
|
| Weight |
Non-reverse: 3.3 kg @ DC
|
| Conductor cross section |
Top opening: 16 to 50 mm²
|
| Protection class |
IP00 IEC 60529/DIN 40050
|
| Altitude of installation site, max |
2000 m (NN) per IEC 60947-4
|
|---|---|
| Protection against accidental contact |
Finger and back-of-hand proof per VDE 0106, part 100
|
| Ambient temperature |
Storage: -40...80 °C
|
| Single contactor cover |
IP10 IEC 60529/DIN 40050
|
|---|---|
| Contactor with frame terminal block |
IP20 IEC 60529/DIN 40050
|
| 类型 | 资源 | 出版 |
|---|---|---|
| Installation Instructions | 100s-in009_-en-e | 100S-IN009 |
| Technical Data | 100-td013_-en-p | 100-TD013 |
技术规格
| Voltage type for actuating |
AC/DC
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
208 V
|
| Rated control supply voltage at AC 60 Hz |
208 V
|
| Rated control supply voltage at DC |
200 V
|
| Type of electrical connection of main circuit |
Screw connection
|
| Rated impulse withstand voltage (Uimp) |
12 kV
|
| Current (Ie), max |
115 A
|
| Current rating |
115 A
|
| Main current circuit resistance |
0.4 mΩ
|
| Rated filament current |
120A @ 230/240V, AC-5b
|
| Rated isolation voltage (Ui) |
600V per UL, CSA
|
| Auxiliary contacts |
IP20 IEC 60529/DIN 40050
|
| Rated power (enclosed) |
75Hp @ 460V, 3-phase per UL/CSA
|
| Rated operational current for contactor |
80A @ 230V, elevator duty (UL/CSA)
|
| Rated power for contactor |
75Hp @ 575V, elevator duty (UL/CSA)
|
| Auxiliary contact configuration |
2 NO, 2 NC auxiliary
|
| Rating of single capacitor |
97 kVAR @ 500V @ 50Hz, AC-6b, 40 °C
|
| Rating of group capacitors |
58 kVAR @ 1000V @ 50Hz, AC-6b, 60 °C
|
| General purpose current (enclosed) |
Load carrying capacity: 220 A per UL/CSA
|
| Operating time, closing delay |
Electronic coil: 9...18 ms @ RC module
|
| Power dissipation |
14.5 W @ 400V, AC-3, Ie
|
| Short time withstand (Icw) |
1040A @ 10s, 60 °C
|
| Operating time, opening delay |
Electronic coil: 6...12 ms @ AC
|
| Coil consumption, hold-in |
Electronic coil: 8 W @ DC control
|
| Coil consumption, pick-up |
Electronic coil: 650VA @ 50 Hz, 60 Hz, 50/60 Hz
|
| Total power dissipation |
DC control: 22.5 W @ 400V, AC-3, Ie
|
| Operating limits, dropout |
Electronic coil: (0.3...0.6) x Us @ DC control
|
| Switching of lamps |
Gas discharge lA, open: 144A @ 40°C, AC-5a
|
| Insulation class of the coil |
Class B per VDE 0660, table 22
|
| Rating for switching AC motors |
80 kW @ 500V @ 50Hz, 3-phase (AC-2, AC-3)
|
| Switching of hermetically sealed cooling compressor motors |
192A @ 690V, AC-8a (manual reset of overload release (50 Hz))
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ DC control
|
| BS88 fuses current rating |
Type2 (IEC 60947-4-1): 200A @ 415V, 65 kA available fault current
|
| UL class K5 and RK5 fuses rating |
250A @ 600V, 10 kA available fault current per UL listed combination
|
| DIN fuses (gG, gL) current rating |
Type2 (IEC 60947-4-1): 200A @ 690V, 50 kA available fault current
|
| Coil voltage |
208-277V 50/60 Hz/230-250 50/60 Hz/200-255V DC electronic coil with electronic interface
|
| Rated operational current (Ie) |
Conventional coil type: 115A @ 690V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C
|
| UL class J and CSA HRCI-J fuses rating |
Type2 (IEC60947-4-1): 200A @ 100kA available fault current per UL verified combination
|
| UL inverse-time circuit breaker |
150A @ 600V, 10 kA available fault current per UL listed combination
|
| Switching of power transformers |
Apparent power: 99.8 kVA @ 480V @ 60Hz
|
| Rated operational power (Pe) |
87 kW @ 240V, AC-1 (50 Hz), ambient temperature 60 °C
|
| Switching of DC loads |
3-pole in series: 3A @ 440V (shunt-wound motors, starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
|
| Optional accessories |
Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
|
| Features |
Mirror contact performance on auxiliary contacts, which are required in ftdback circuit for modern safety applications, The NC auxiliary contacts will not change state when a power contact welds, SUVA third-party certification, AC and DC operating coils,
|
| Contacts |
3 main poles with N.C. mechanically linked ftdback contacts
|
| Conventional coil type |
Yes
|
| Electronic-EI coil type |
Yes
|
| Screw terminals |
Thru-hole
|
|---|---|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Main contact terminal conductor cross section |
8.3 mm @ minimum Ø
|
| Frame terminal block conductor cross section |
3...9 mm @ s top
|
| Lifespan |
Mechanical DC control: 10000000 ops
|
| Switching frequency, max |
120 ops/h, AC-4 (approximately 200000 ops)
|
| Recommended torque |
88 to 106 in-lb
|
| Weight |
Non-reverse: 3.3 kg @ DC
|
| Conductor cross section |
Top opening: 16 to 50 mm²
|
| Protection class |
IP00 IEC 60529/DIN 40050
|
| Altitude of installation site, max |
2000 m (NN) per IEC 60947-4
|
|---|---|
| Protection against accidental contact |
Finger and back-of-hand proof per VDE 0106, part 100
|
| Ambient temperature |
Storage: -40...80 °C
|
| Single contactor cover |
IP10 IEC 60529/DIN 40050
|
|---|---|
| Contactor with frame terminal block |
IP20 IEC 60529/DIN 40050
|
文档
|
100s-in009_-en-e
Installation Instructions
100S-IN009 |
|
100-td013_-en-p
Technical Data
100-TD013 |
| 类型 | 资源 | 出版 |
|---|---|---|
| Installation Instructions | 100s-in009_-en-e | 100S-IN009 |
| Technical Data | 100-td013_-en-p | 100-TD013 |