| Number of normally open contacts as main contact |
4
|
|---|---|
| Number of normally closed contacts as main contact |
0
|
| Number of auxiliary contacts as normally open contact |
0
|
| Number of auxiliary contacts as normally closed contact |
0
|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Altitude, max |
3000 m of installation site
|
| Switching frequency, max |
600 ops/hr, AC-1
|
| Weight |
AC/DC (electronic): 0.48 kg (1.06 lbs.)
|
| Protection class |
Contactor main contact: IP2X
|
| Voltage type for actuating |
DC
|
|---|---|
| Rated control supply voltage at DC |
0 V
|
| Type of electrical connection of main circuit |
Screw connection
|
| Rated impulse voltage withstand (Uimp) |
6 kV
|
| Operating time, closing delay |
17 ms
|
| Operating time, opening delay |
11 ms
|
| Optional overload relays |
Electronic
|
| High energy efficient coil, pick-up |
6 W @ 24V DC
|
| High energy efficient coil, hold-in |
1.7 W @ 24V DC
|
| Main current circuit resistance |
0.29 mΩ
|
| Rated isolation voltage (Ui) |
690V per IEC
|
| Function |
Non-reversing contactor
|
| General purpose current (enclosed) |
24A @ 600V per UL/CSA
|
| Power dissipation |
2.4 W per pole at Ie, AC-1, 400V
|
| Short time withstand (Icw) |
3-pole: 700A @ 1s (40 °C)
|
| FLA |
45A @ 600V, 3-phase per UL/CSA HVAC applications
|
| Rated operational current and power (enclosed) |
7.5 Hp @ 220-240V, 3-phase per UL/CSA
|
| LRA |
270 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
|
| Electromagnetic compatibility |
IEC 60947-1 - Environment A and B (100-E09...E38 only.)
|
| Total power dissipation |
4.7 W at Ie, AC-3, 400V, AC/DC control (120-250V)
|
| Operating limits, dropout |
(≤0.60) x Us @ DC control
|
| Rating for switching AC motors |
3-poles: 7.5Hp @ 230V, AC-2, AC-3 (60 Hz)
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50/60 Hz
|
| MCCB current rating |
Type 2 (per IEC 60947-4-1): 56A @ 400V, 70 kA available fault current
|
| DIN fuses (gG) current rating |
Type 2 (per IEC 60947-4-1): 62A @ 400V, 100 kA available fault current
|
| Rated voltage (Ue) |
24V @ 48V, 110V @ 220V, 440V DC
|
| Rated operational current and power |
9.6A @ 230V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty
|
| Switching of lighting loads |
Tungsten lA: 45A @ 600V, 3-phase (break all lines) per UL/CSA
|
| UL class RK5 fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 5 kA available fault current
|
| Rated operational current (Ie) |
4-poles: 45A @ 40°C, AC-1 (690V)
|
| UL class J and CSA HRCI-J fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 100 kA available fault current
|
| UL inverse-time circuit breaker |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 100A @ 600V, 25 kA available fault current
|
| Switching of power transformers |
Apparent power: 9 kVA @ 200V @ 60Hz (n = 30)
|
| Rated operational power (Pe) |
6.5 kW @ 220-240V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
|
| Switching of DC loads |
4-poles in series: 45A @ 220V (non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
|
| Optional accessories |
Side-or front-mount auxiliary contacts, Mechanical interlocks, Connecting bars
|
| Features |
Panel mounting or mounting on 35 mm DIN rail, AC/DC electronic coil, Made of environmentally friendly materials
|
| Climatic withstand |
Category B according to IEC 60947-1, annex Q
|
|---|---|
| Ambient temperature |
Storage: -60...80 °C (-76...176 °F)
|
| Coil insulation class |
Class F per IEC 60947-4-1
|
|---|
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Circuit Protection Design and SCCR Tables | -- |
| 应用技巧 | 出版 |
|---|---|
| 100-at003_-en-p | 100-AT003 |
| 技术数据 | 出版 |
|---|---|
| 100-td013_-en-p | 100-TD013 |
- China CCC
- UL Listed
- Australian RCM
- CE
- Eurasion Economic Community
- Korean KC
- Registro Italiano Navale
- Safety
- MOROCCO DOC
截至 2025-11-28,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。
技术规格
| Number of normally open contacts as main contact |
4
|
|---|---|
| Number of normally closed contacts as main contact |
0
|
| Number of auxiliary contacts as normally open contact |
0
|
| Number of auxiliary contacts as normally closed contact |
0
|
| Vibration resistance |
IEC 60068-2-6
|
| Shock resistance |
IEC 60068-2-27
|
| Altitude, max |
3000 m of installation site
|
| Switching frequency, max |
600 ops/hr, AC-1
|
| Weight |
AC/DC (electronic): 0.48 kg (1.06 lbs.)
|
| Protection class |
Contactor main contact: IP2X
|
| Voltage type for actuating |
DC
|
|---|---|
| Rated control supply voltage at DC |
0 V
|
| Type of electrical connection of main circuit |
Screw connection
|
| Rated impulse voltage withstand (Uimp) |
6 kV
|
| Operating time, closing delay |
17 ms
|
| Operating time, opening delay |
11 ms
|
| Optional overload relays |
Electronic
|
| High energy efficient coil, pick-up |
6 W @ 24V DC
|
| High energy efficient coil, hold-in |
1.7 W @ 24V DC
|
| Main current circuit resistance |
0.29 mΩ
|
| Rated isolation voltage (Ui) |
690V per IEC
|
| Function |
Non-reversing contactor
|
| General purpose current (enclosed) |
24A @ 600V per UL/CSA
|
| Power dissipation |
2.4 W per pole at Ie, AC-1, 400V
|
| Short time withstand (Icw) |
3-pole: 700A @ 1s (40 °C)
|
| FLA |
45A @ 600V, 3-phase per UL/CSA HVAC applications
|
| Rated operational current and power (enclosed) |
7.5 Hp @ 220-240V, 3-phase per UL/CSA
|
| LRA |
270 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
|
| Electromagnetic compatibility |
IEC 60947-1 - Environment A and B (100-E09...E38 only.)
|
| Total power dissipation |
4.7 W at Ie, AC-3, 400V, AC/DC control (120-250V)
|
| Operating limits, dropout |
(≤0.60) x Us @ DC control
|
| Rating for switching AC motors |
3-poles: 7.5Hp @ 230V, AC-2, AC-3 (60 Hz)
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50/60 Hz
|
| MCCB current rating |
Type 2 (per IEC 60947-4-1): 56A @ 400V, 70 kA available fault current
|
| DIN fuses (gG) current rating |
Type 2 (per IEC 60947-4-1): 62A @ 400V, 100 kA available fault current
|
| Rated voltage (Ue) |
24V @ 48V, 110V @ 220V, 440V DC
|
| Rated operational current and power |
9.6A @ 230V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty
|
| Switching of lighting loads |
Tungsten lA: 45A @ 600V, 3-phase (break all lines) per UL/CSA
|
| UL class RK5 fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 5 kA available fault current
|
| Rated operational current (Ie) |
4-poles: 45A @ 40°C, AC-1 (690V)
|
| UL class J and CSA HRCI-J fuses rating |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 100 kA available fault current
|
| UL inverse-time circuit breaker |
Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 100A @ 600V, 25 kA available fault current
|
| Switching of power transformers |
Apparent power: 9 kVA @ 200V @ 60Hz (n = 30)
|
| Rated operational power (Pe) |
6.5 kW @ 220-240V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
|
| Switching of DC loads |
4-poles in series: 45A @ 220V (non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
|
| Optional accessories |
Side-or front-mount auxiliary contacts, Mechanical interlocks, Connecting bars
|
| Features |
Panel mounting or mounting on 35 mm DIN rail, AC/DC electronic coil, Made of environmentally friendly materials
|
| Climatic withstand |
Category B according to IEC 60947-1, annex Q
|
|---|---|
| Ambient temperature |
Storage: -60...80 °C (-76...176 °F)
|
| Coil insulation class |
Class F per IEC 60947-4-1
|
|---|
文档
|
Product Cutsheet
基本信息
-- |
|
Circuit Protection Design and SCCR Tables
基本信息
-- |
|
100-at003_-en-p
应用技巧
100-AT003 |
|
100-td013_-en-p
技术数据
100-TD013 |
| 基本信息 | 出版 |
|---|---|
| Product Cutsheet | -- |
| Circuit Protection Design and SCCR Tables | -- |
| 应用技巧 | 出版 |
| 100-at003_-en-p | 100-AT003 |
| 技术数据 | 出版 |
| 100-td013_-en-p | 100-TD013 |
认证
- China CCC
- UL Listed
- Australian RCM
- CE
- Eurasion Economic Community
- Korean KC
- Registro Italiano Navale
- Safety
- MOROCCO DOC
截至 2025-11-28,此产品已获得上述多项认证。此日期前后销售的产品,所获认证可能有所不同。请查阅产品标签,确认具体产品所持有的相关认证。