Rockwell Automation announces that as of March 31, 2019, the IEC 860 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s).
Discontinued Date: March 31, 2019 Replacement Category: Engineering Replacement 替换产品: 100-E750ED11 [https://www.rockwellautomation.com.cn/products/details.100-E750ED11.html]
Allen-Bradley 100-D860EA11 product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Discontinued
ErrorsErrors
Rockwell Automation announces that as of March 31, 2019, the IEC 860 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s).
Discontinued Date: March 31, 2019 Replacement Category: Engineering Replacement 替换产品: 100-E750ED11 [https://www.rockwellautomation.com.cn/products/details.100-E750ED11.html]
Add to BoM
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Documents
Technotes
Auxiliary Contact Cnfg 1 N.O. 1 N.C.
Coil Code 208-277V 50/60Hz / 200-255V DC @ 220V DC (Electronic Coil)
Maximum Ampere Rating 860 A
Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 208 V
Rated control supply voltage at AC 60 Hz 208 V
Rated control supply voltage at DC 200 V
Type of electrical connection of main circuit Screw connection
Rated impulse withstand voltage (Uimp) 12 kV
Current (Ie), max 860 A
Optional overload relays Electronic
Current rating 115 A
Main current circuit resistance 0.14 mΩ
Rated isolation voltage (Ui) 600V @ UL, CSA
Auxiliary contacts IP20 IEC 60529/DIN 40050
Rated power (enclosed) 700Hp @ 575V, 3-phase per UL/CSA
General purpose current (enclosed) 860 A per UL/CSA
Power dissipation 310.6 W @ 400V, AC-3, Ie
Operating time 70…145 ms @ DC, closing delay
Short time withstand (Icw) 7000A @ 10s, 60 °C (140 °F)
Coil consumption, hold-in 33VA/30 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up 1980 W @ DC control
Total power dissipation DC control: 340.6 W @ 400V, AC-3, Ie
Operating limits, dropout (0.1...0.8) x Us @ DC control
Insulation class of the coil Class B per VDE 0660, table 22
Rating for switching AC motors 700Hp @ 575V, 60 Hz, 3-phase (AC-2, AC-3)
Operating limits, pick-up (0.85...1.1) x Us @ DC control
BS88 fuses current rating TBD
UL class L fuses rating 2500A @ 600V, 42 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated voltage (Ue) 690V @ AC, 50/60 Hz
DIN fuses (gG, gL) current rating TBD
Coil voltage 208-277V 50/60 Hz/230-250 50/60 Hz/200-255V DC electronic coil w/ electronic interface
Rated operational current (Ie) 860A @ 60°C, AC-3
UL inverse-time circuit breaker 1200A @ 600V, 42 kA available fault current per UL listed combination
Rated operational power (Pe) 866 kW @ 500V, AC-1 (50 Hz), ambient temperature 40 °C
Optional accessories Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
Features Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil)
Contacts 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks
Conventional coil type True
Electronic-EI coil type True
Rated coil frequency AC 50 Hz, 50/60 Hz DC
Screw terminals Threaded
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Cross section per UL/CSA (4X) 2/0...500 MCM
Lifespan Mechanical DC control: 2000000 ops
Recommended torque 68 Nm
Weight Non-reverse: 28.6 kg @ DC
Conductor cross section Main contact, s maximum: 16 mm
Protection class IP00 IEC 60529/DIN 40050
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE 0106, part 100
Ambient temperature Storage: -40…80 °C
Single contactor cover IP10 IEC 60529/DIN 40050
Contactor with frame terminal block IP20 IEC 60529/DIN 40050
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 37.0
Lead Time 17
Dimension Width 51.001
Dimension Length 40.5
Stock Status NON_STOCKED
Weight 33.0
Weight Unit KG
Dimension Unit CM
类型 资源 发布
Installation Instructions 100-in042_-mu-e 100-IN042
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Auxiliary Contact Cnfg 1 N.O. 1 N.C.
Coil Code 208-277V 50/60Hz / 200-255V DC @ 220V DC (Electronic Coil)
Maximum Ampere Rating 860 A
Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 208 V
Rated control supply voltage at AC 60 Hz 208 V
Rated control supply voltage at DC 200 V
Type of electrical connection of main circuit Screw connection
Rated impulse withstand voltage (Uimp) 12 kV
Current (Ie), max 860 A
Optional overload relays Electronic
Current rating 115 A
Main current circuit resistance 0.14 mΩ
Rated isolation voltage (Ui) 600V @ UL, CSA
Auxiliary contacts IP20 IEC 60529/DIN 40050
Rated power (enclosed) 700Hp @ 575V, 3-phase per UL/CSA
General purpose current (enclosed) 860 A per UL/CSA
Power dissipation 310.6 W @ 400V, AC-3, Ie
Operating time 70…145 ms @ DC, closing delay
Short time withstand (Icw) 7000A @ 10s, 60 °C (140 °F)
Coil consumption, hold-in 33VA/30 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up 1980 W @ DC control
Total power dissipation DC control: 340.6 W @ 400V, AC-3, Ie
Operating limits, dropout (0.1...0.8) x Us @ DC control
Insulation class of the coil Class B per VDE 0660, table 22
Rating for switching AC motors 700Hp @ 575V, 60 Hz, 3-phase (AC-2, AC-3)
Operating limits, pick-up (0.85...1.1) x Us @ DC control
BS88 fuses current rating TBD
UL class L fuses rating 2500A @ 600V, 42 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated voltage (Ue) 690V @ AC, 50/60 Hz
DIN fuses (gG, gL) current rating TBD
Coil voltage 208-277V 50/60 Hz/230-250 50/60 Hz/200-255V DC electronic coil w/ electronic interface
Rated operational current (Ie) 860A @ 60°C, AC-3
UL inverse-time circuit breaker 1200A @ 600V, 42 kA available fault current per UL listed combination
Rated operational power (Pe) 866 kW @ 500V, AC-1 (50 Hz), ambient temperature 40 °C
Optional accessories Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
Features Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil)
Contacts 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks
Conventional coil type True
Electronic-EI coil type True
Rated coil frequency AC 50 Hz, 50/60 Hz DC
Screw terminals Threaded
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Cross section per UL/CSA (4X) 2/0...500 MCM
Lifespan Mechanical DC control: 2000000 ops
Recommended torque 68 Nm
Weight Non-reverse: 28.6 kg @ DC
Conductor cross section Main contact, s maximum: 16 mm
Protection class IP00 IEC 60529/DIN 40050
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE 0106, part 100
Ambient temperature Storage: -40…80 °C
Single contactor cover IP10 IEC 60529/DIN 40050
Contactor with frame terminal block IP20 IEC 60529/DIN 40050
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 37.0
Lead Time 17
Dimension Width 51.001
Dimension Length 40.5
Stock Status NON_STOCKED
Weight 33.0
Weight Unit KG
Dimension Unit CM
文档
100-in042_-mu-e Installation Instructions
100-IN042
100-td013_-en-p Technical Data
100-TD013
类型 资源 发布
Installation Instructions 100-in042_-mu-e 100-IN042
Technical Data 100-td013_-en-p 100-TD013
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
IEC 860 A MCS D Contactor
CloseClose
100-D860EA11
关闭
打印
Allen-Bradley 100-D860EA11 product image
手机:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation 主页 Chevron RightChevron Right
  2. Chevron LeftChevron Left 产品 Chevron RightChevron Right
请更新您的Cookies偏好以继续.
此功能需要Cookies来增强您的体验。请更新您的系统偏好以允许使用这些Cookies:
  • 社交媒体Cookies
  • 功能Cookies
  • 性能 Cookies
  • 市场营销Cookies
  • 所有Cookies
您可以随时更新您的系统偏好。如需了解更多信息,请参阅我们的 {0} 隐私政策
CloseClose