100-D180ED11
IEC 180 A MCS D Contactor
Rockwell Automation announces that as of March 31, 2019, the IEC 180 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
March 31, 2019
替代类别:
Engineering Replacement
替代产品:
100-E190KD11
[https://www.rockwellautomation.com.cn/products/details.100-E190KD11.html]
Product at a glance
Rockwell Automation announces that as of March 31, 2019, the IEC 180 A MCS D Contactor will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
停产日期:
March 31, 2019
替代类别:
Engineering Replacement
替代产品:
100-E190KD11
[https://www.rockwellautomation.com.cn/products/details.100-E190KD11.html]
Product at a glance
Auxiliary Contact Cnfg | 1 N.O. 1 N.C. |
---|---|
Coil Code | 110-130V 50/60Hz / 110-130V DC |
Maximum Ampere Rating | 180 A |
Product Family | IEC |
Voltage type for actuating | AC/DC |
---|---|
Rated control supply voltage at AC 50 Hz | 110 V |
Rated control supply voltage at AC 60 Hz | 110 V |
Rated control supply voltage at DC | 110 V |
Type of electrical connection of main circuit | Screw connection |
Rated impulse withstand voltage (Uimp) | 12 kV |
Current (Ie), max | 180 A |
Optional overload relays | Electronic |
Current rating | 115 A |
Main current circuit resistance | 0.42 mΩ |
Rated filament current | 170A @ 230/240V, AC-5b |
Rated isolation voltage (Ui) | 600V @ UL, CSA |
Auxiliary contacts | IP20 IEC 60529/DIN 40050 |
Rated power (enclosed) | 60Hp @ 230V, 3-phase per UL/CSA |
Rated operational current for contactor | 99A @ 575V, elevator duty (UL/CSA) |
Rated power for contactor | 75Hp @ 200V, wye-delta (60 Hz) |
General purpose current (enclosed) | 220 A per UL/CSA |
Power dissipation | 40.8 W @ 400V, AC-3, Ie |
Operating time | 9…18 ms @ RC module, closing delay |
Short time withstand (Icw) | 1480A @ 10s, 60 °C (140 °F) |
Coil consumption, hold-in | 8 W @ DC control |
Coil consumption, pick-up | 650VA/310 W @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of 3-phase Capacitors | Single capacitor: 80 kVAR @ 230V, AC-6b, 60 Hz, 40 °C |
Total power dissipation | DC control (electronic coil): 46.8 W @ 400V, AC-3, Ie |
Operating limits, dropout | (0.3...0.6) x Us @ DC control |
Switching of lamps | Gas discharge lA, open: 225A @ 40°C (104 °F), AC-5a |
Insulation class of the coil | Class B per VDE 0660, table 22 |
Rating for switching AC motors | 90 kW @ 690V @ 50Hz, 3-phase (AC-2, AC-3) |
Operating limits, pick-up | (0.85...1.1) x Us @ DC control |
BS88 fuses current rating | Type 2 (per IEC 60947-4-1): 250A @ 415V, 65 kA available fault current |
UL class K5 and RK5 fuses rating | 450A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Rated voltage (Ue) | 690V @ AC, 50/60 Hz |
DIN fuses (gG, gL) current rating | Type 2 (per IEC 60947-4-1): 315A @ 690V, 50 kA available fault current |
Coil voltage | 110-130V 50/60 Hz/110-130V DC electronic coil w/ electronic interface |
Rated operational current (Ie) | Electronic-EI coil type: 180A @ 500V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C |
UL class J and CSA HRCI-J fuses rating | Type2 (IEC60947-4-1): 300A @ 100kA available fault current per UL verified combination |
UL inverse-time circuit breaker | 250A @ 600V, 10 kA available fault current per UL listed combination |
Switching of power transformers | Apparent power: 97.2 kVA @ 660V, AC-6a @ 60Hz (n = 30) |
Rated operational power (Pe) | 98 kW @ 500V, AC-4 (50 Hz), ambient temperature 60 °C |
Switching of DC loads | 3-Poles in series: 210A @ 48/60V (Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
Optional accessories | Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks |
Features | Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil) |
Contacts | 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks |
Conventional coil type | True |
Electronic-EI coil type | True |
Rated coil frequency | AC 50 Hz, 50/60 Hz DC |
Frame terminal block conductor cross section, b max | 20 |
---|---|
Frame terminal block conductor cross section, s top | 3 |
Frame terminal block conductor cross section, s bottom | 3 |
Screw terminals | Thru-hole |
Conductor cross section, top opening | 16 |
Conductor cross section, bottom opening | 16 |
Vibration resistance | IEC 60068-2-6 |
Shock resistance | IEC 60068-2-27 |
Cross section per UL/CSA | 6...300 MCM |
Lifespan | Mechanical DC control: 10000000 ops |
Switching frequency, max | 100 ops/h |
Recommended torque | 88 to 106 in-lb |
Weight | Non-reverse (Electronic-EI coil type): 3.8 kg @ DC |
Conductor cross section | Main contact, s maximum: 5 mm |
Protection class | IP00 IEC 60529/DIN 40050 |
Width | 255 mm |
---|---|
Height | 337.5 mm |
Depth | 266.25 mm |
Single contactor cover | IP10 IEC 60529/DIN 40050 |
Contactor with frame terminal block | IP20 IEC 60529/DIN 40050 |
Altitude of installation site, max | 2000 m (NN), per IEC60947-1 |
---|---|
Protection against accidental contact | Finger-and back-of-hand proof per VDE 0106, part 100 |
Ambient temperature | Storage: -40…80 °C |
类型 | 资源 | 出版 |
---|---|---|
Installation Instructions | 100-in042_-mu-e | 100-IN042 |
Technical Data | 100-td013_-en-p | 100-TD013 |
技术规格
Auxiliary Contact Cnfg | 1 N.O. 1 N.C. |
---|---|
Coil Code | 110-130V 50/60Hz / 110-130V DC |
Maximum Ampere Rating | 180 A |
Product Family | IEC |
Voltage type for actuating | AC/DC |
---|---|
Rated control supply voltage at AC 50 Hz | 110 V |
Rated control supply voltage at AC 60 Hz | 110 V |
Rated control supply voltage at DC | 110 V |
Type of electrical connection of main circuit | Screw connection |
Rated impulse withstand voltage (Uimp) | 12 kV |
Current (Ie), max | 180 A |
Optional overload relays | Electronic |
Current rating | 115 A |
Main current circuit resistance | 0.42 mΩ |
Rated filament current | 170A @ 230/240V, AC-5b |
Rated isolation voltage (Ui) | 600V @ UL, CSA |
Auxiliary contacts | IP20 IEC 60529/DIN 40050 |
Rated power (enclosed) | 60Hp @ 230V, 3-phase per UL/CSA |
Rated operational current for contactor | 99A @ 575V, elevator duty (UL/CSA) |
Rated power for contactor | 75Hp @ 200V, wye-delta (60 Hz) |
General purpose current (enclosed) | 220 A per UL/CSA |
Power dissipation | 40.8 W @ 400V, AC-3, Ie |
Operating time | 9…18 ms @ RC module, closing delay |
Short time withstand (Icw) | 1480A @ 10s, 60 °C (140 °F) |
Coil consumption, hold-in | 8 W @ DC control |
Coil consumption, pick-up | 650VA/310 W @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of 3-phase Capacitors | Single capacitor: 80 kVAR @ 230V, AC-6b, 60 Hz, 40 °C |
Total power dissipation | DC control (electronic coil): 46.8 W @ 400V, AC-3, Ie |
Operating limits, dropout | (0.3...0.6) x Us @ DC control |
Switching of lamps | Gas discharge lA, open: 225A @ 40°C (104 °F), AC-5a |
Insulation class of the coil | Class B per VDE 0660, table 22 |
Rating for switching AC motors | 90 kW @ 690V @ 50Hz, 3-phase (AC-2, AC-3) |
Operating limits, pick-up | (0.85...1.1) x Us @ DC control |
BS88 fuses current rating | Type 2 (per IEC 60947-4-1): 250A @ 415V, 65 kA available fault current |
UL class K5 and RK5 fuses rating | 450A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Rated voltage (Ue) | 690V @ AC, 50/60 Hz |
DIN fuses (gG, gL) current rating | Type 2 (per IEC 60947-4-1): 315A @ 690V, 50 kA available fault current |
Coil voltage | 110-130V 50/60 Hz/110-130V DC electronic coil w/ electronic interface |
Rated operational current (Ie) | Electronic-EI coil type: 180A @ 500V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C |
UL class J and CSA HRCI-J fuses rating | Type2 (IEC60947-4-1): 300A @ 100kA available fault current per UL verified combination |
UL inverse-time circuit breaker | 250A @ 600V, 10 kA available fault current per UL listed combination |
Switching of power transformers | Apparent power: 97.2 kVA @ 660V, AC-6a @ 60Hz (n = 30) |
Rated operational power (Pe) | 98 kW @ 500V, AC-4 (50 Hz), ambient temperature 60 °C |
Switching of DC loads | 3-Poles in series: 210A @ 48/60V (Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
Optional accessories | Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks |
Features | Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil) |
Contacts | 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks |
Conventional coil type | True |
Electronic-EI coil type | True |
Rated coil frequency | AC 50 Hz, 50/60 Hz DC |
Frame terminal block conductor cross section, b max | 20 |
---|---|
Frame terminal block conductor cross section, s top | 3 |
Frame terminal block conductor cross section, s bottom | 3 |
Screw terminals | Thru-hole |
Conductor cross section, top opening | 16 |
Conductor cross section, bottom opening | 16 |
Vibration resistance | IEC 60068-2-6 |
Shock resistance | IEC 60068-2-27 |
Cross section per UL/CSA | 6...300 MCM |
Lifespan | Mechanical DC control: 10000000 ops |
Switching frequency, max | 100 ops/h |
Recommended torque | 88 to 106 in-lb |
Weight | Non-reverse (Electronic-EI coil type): 3.8 kg @ DC |
Conductor cross section | Main contact, s maximum: 5 mm |
Protection class | IP00 IEC 60529/DIN 40050 |
Width | 255 mm |
---|---|
Height | 337.5 mm |
Depth | 266.25 mm |
Single contactor cover | IP10 IEC 60529/DIN 40050 |
Contactor with frame terminal block | IP20 IEC 60529/DIN 40050 |
Altitude of installation site, max | 2000 m (NN), per IEC60947-1 |
---|---|
Protection against accidental contact | Finger-and back-of-hand proof per VDE 0106, part 100 |
Ambient temperature | Storage: -40…80 °C |
文档
100-in042_-mu-e
Installation Instructions
100-IN042 |
100-td013_-en-p
Technical Data
100-TD013 |
类型 | 资源 | 出版 |
---|---|---|
Installation Instructions | 100-in042_-mu-e | 100-IN042 |
Technical Data | 100-td013_-en-p | 100-TD013 |
技术说明
Loading
Copyright ©2025 Rockwell Automation, Inc.