Additional Fault Information: 1756-PLS
The following table lists the additional fault information for the 1756-PLS module Axis Configuration.
Code: | Explanation and Possible Causes/Solutions: |
16#0008 | RPMFilter out of range. Check that the value entered is between 16#1000 and 16#ffff. |
16#0010 | RolloverPosition out of range. Check that the value entered is less than 16#ffff. |
16#0012 | RolloverCounts out of range. Check that the value entered is less than 16#ffff. |
16#0018 | PresetInput is greater than 31. Enter a value less than 31. |
16#0019 | NudgeUpInput is greater than 31. Enter a value less than 31. |
16#0020 | NudgeDownInput is greater than 31. Enter a value less than 31. |
16#0022 | The ZeroOffset value exceeds the value of RolloverPosition. Check that the ZeroOffset entered is less than or equal to the RolloverPosition value. |
16#0024 | Preset exceeds RolloverPosition. Enter a value less than the RolloverPosition value. |
16#0026 | NudgeUpOffset exceeds the value of RolloverPosition. Check that the NudgeUpOffset entered is less than or equal to the RolloverPosition value. |
16#0028 | NudgeDownOffset exceeds the value of RolloverPosition. Check that the NudgeDownOffset entered is less than or equal to the RolloverPosition value. |
Provide Feedback